Home › DC Trax › DC Trax › DC Trax™ Parallel String Harness
Multi-String Combination

DC Trax™ Parallel String Harness

Multi-String Combination — Saves 50% Solar Cable

Merges two or more PV module strings into a single DC line before routing to the inverter. Saves up to 50% of solar cable versus single-string systems. Produced using unique dual-moulding or vulcanisation process guaranteeing maximum impermeability, outstanding mechanical properties, and high temperature resistance.

1500 VDC 50% Cable Saving IP68 Rated 25+ Year Life Saltwater Resistant
parallel-string-harness Zoom
1500V Max Voltage
50% Cable Reduction
IP68 IP Rating
70A Free-Air Rating (6mm²)
120°C Max Conductor Temp
25+yr Service Life
7yr Warranty
Model Range

Parallel Harness Configurations

ModelTypeDescriptionApplications
DC Trax Y-PlugY-ConnectorMerges 2 strings into 1 line (single polarity)Crystalline Si modules
DC Trax ES-2Single polarity 2-way2-junction single polarity harnessAll module types
DC Trax ES-4Single polarity 4-way4-junction single polarity harnessThin-film & crystalline
DC Trax ES-5Single polarity 5-way5-junction single polarity harnessLarge-scale thin-film
DC Trax DS SeriesDual polarityDual-polarity with integrated fuses and diodesAll module types
Rated Voltage Up to 1500 VDC
Insulation Material XLPO-Compound, 120°C dual mould
Ambient Temperature Range −40°C to +90°C
Max. Operating Temperature (Conductor) −40°C to +120°C
Ozone Resistance Compliant to 2PfG 1913/03.21
UV Resistance Compliant to 2PfG 1913/03.21
Moisture Resistance 1000 h at 90°C and 85% humidity (DIN EN 60068-2-78)
Long-term DC Insulation 240 h, 1.5 kV DC in water at 85°C (2PfG 1913/03.21)
Ammonia Resistance 30 days saturated NH₃ atmosphere
IP Rating IP68 (1 h/1 m vulcanised; 10 days/1 m moulded)
Spark Test 16 kV AC
Dielectric Strength 6.5 kV AC (5 min) in water (2PfG 1913/03.21)
Contact Resistance ≤0.5 mΩ at moulding splice output
Conductor Tinned stranded copper, Class 5 (IEC 60228)
Conductor Diameters 2.5 mm², 4 mm², 6 mm², 10 mm²
Design Life 30+ years
Warranty 7 years standard
Single cable free in air (6 mm²)70A
Single cable on a surface (6 mm²)67A
Two loaded cables touching (6 mm²)57A
Halogen FreeCompliant to EN 50525-1, Appendix B
Low Smoke / ToxicityDIN EN 50268-2 / DIN EN 50305
FlammabilitySingle cable DIN EN 60332-1-2; Multi-cable DIN EN 50305-9
StandardsTUV 2PfG 1913/03.21, IEC 62852, IEC 62930
Solar CableEN 50618 (Solar Cable Standard)
PV ConnectorsIEC 62852
PV System DesignIEC 62548
PV InstallationsAS/NZS 5033

Specify the DC Trax™ Parallel Harness

Custom configured for your string layout, module type, and cable lengths.

EESA Typically replies in minutes