Insulation Piercing Connector for DC Bus
Attaches string leads directly to a double-insulated DC busbar — without stripping bus cable insulation. Shear-head bolts at predetermined torque ensure a reliable, repeatable connection every time. Factory kitted with inline fuses and pre-terminated MC4 connectors for true plug-and-play installation using only a standard impact driver.
| Model | String Connections | Bus Cable Range | String Cable | Connection Method |
|---|---|---|---|---|
| DC Trax IPC-6W | 1–6 strings | 95–500 mm² (double insulated) | 4–16 mm² | Shear-head bolt IPC |
| DC Trax IPC-4W | 1–4 strings | 35–120 mm² (double insulated) | 4–16 mm² | Shear-head bolt IPC |
| DC Trax IPC-2W | 2 strings | 35–240 mm² (double insulated) | 4–16 mm² | Shear-head bolt IPC |
| Rated Voltage | 1500 VDC |
| Fuse Current Range | 15A – 40A (inline cartridge fuse) · 15A, 20A, 25A, 30A, 35A, 40A |
| Bus Cable Range | 35 mm² – 500 mm² (double insulated, Cu or Al) |
| String Cable Range | 4 mm² – 16 mm² (tinned copper, class 5) |
| Connection Technology | Insulation Piercing Connector (IPC) with shear-head bolt |
| Dielectric Withstand | 6.5 kV AC for 5 minutes — 1 metre underwater |
| IP Rating | IP66 equivalent (fully sealed) |
| Connector Type | MC4 (Multi-Contact) or customer preferred pre-terminated |
| Polarity Identification | Red (positive) / Black (negative) shear-head bolts |
| Operating Temperature | −40°C to +90°C ambient |
| Design Life | 30+ years |
| Warranty | 7 years standard |
| Cable Standard | EN 50618:2014 / TUV 2PfG 1169/08.07 |
| Test Standard | AS/NZS and IEC type tested |
| Solar Cable | EN 50618, IEC 62930, TUV 2PfG 1169/08.07 |
| System Compliance | AS/NZS 5033, IEC 62930, IEC 62852 |
Custom-engineered to your tracker layout, string configuration, and module type.