Infrastructure — Buildings, Airports & Roads

Built to Last.
Wired to Code.

Power cables, fire-resistant cables, fire rated junction boxes, and fire rated HV cables for public infrastructure — buildings, airports, bridges, and roads — across Australia, New Zealand, and the Pacific Islands.

AS/NZS 1125 · AS/NZS 5000.1 · AS/NZS 5000.2 · AS/NZS 1429.1 · AS/NZS 3013 · AS/NZS 4507
LV HV LV & HV Power Cables Up to 1 kV LV and MV up to 66 kV
FR FD Fire-Resistant & Flame Retardant Safe installations in public infrastructure
CTL INS Control & Instrumentation General purpose power, control & industrial
JBX Fire Rated Junction Boxes Fire rated HV cables & enclosures
LV to 66 kV
Full Voltage Range
6
AS/NZS Standards
Fire Rated
Cables & Enclosures
AU · NZ · PAC
Regional Coverage

Industry Snapshot

What Infrastructure Projects Demand

Public infrastructure projects — airports, hospitals, tunnels, bridges, and road networks — require cables that meet strict fire performance, reliability, and compliance standards. EESA supplies the complete cable and enclosure range for these critical environments.

01
Fire Performance

Public infrastructure demands cables that maintain circuit integrity and limit flame spread in emergency conditions — fire-resistant and flame retardant cables to AS/NZS 3013 and AS/NZS 4507.

02
Full Voltage Range

From LV distribution (up to 1 kV) through to MV interconnection (up to 66 kV) — EESA covers the complete voltage range required for large-scale infrastructure distribution.

03
General Purpose & Specialty

General purpose power, control, and instrumentation cables alongside specialist fire rated and low smoke cables — all from one qualified supplier.

04
Fire Rated Enclosures

Fire rated junction boxes and fire rated HV cables providing complete circuit protection in high-risk public infrastructure environments.

Product Scope

Cables & Enclosures for Infrastructure

All cable and enclosure products supplied through the Australasian Cables brand — covering the full infrastructure cable scope from general purpose power to fire rated specialist systems.

Power & Specialist Cables
Australasian Cables
The complete cable range for infrastructure — LV to MV, general purpose to fire rated.
AS/NZS 1125 · 5000.1 · 5000.2 · 1429.1 · 3013 · 4507
Power Cables
Low Voltage Power Cables
Distribution to buildings, airports, bridges & roads — up to 1 kV
Medium Voltage Power Cables
MV distribution & interconnection — up to 66 kV
Fire Performance
Fire-Resistant Cables
Maintain circuit integrity during fire — public infrastructure
Flame Retardant Cables
Limit flame spread in safe public installations
Fire Rated HV Cables
High voltage cables with fire rated construction
General Purpose & Control
General Purpose Power Cables
Industrial distribution & general infrastructure supply
Control Cables
Building services & infrastructure control systems
Instrumentation Cables
Signal & data between sensors and control systems
Fire Rated Enclosures
Fire Rated Junction Boxes
Fire rated junction boxes for circuit protection in critical public infrastructure installations.
AS/NZS 3013 · AS/NZS 4507
Enclosures
Fire Rated Junction Boxes
Circuit integrity protection in fire conditions — public infrastructure and buildings
Applications
Airports & Transport Hubs
Tunnels & Underground Infrastructure
Hospitals & Public Buildings
Bridges & Road Infrastructure

Standards Compliance

Certified. Compliant. Specified-Ready.

All EESA infrastructure cable and enclosure products are tested and certified to the applicable Australian and New Zealand standards. Full compliance documentation available for project submissions.

AS/NZS 1125
Conductors in Insulated Cables

Conductor requirements for insulated electric cables used across the full LV and MV infrastructure cable range.

AS/NZS 5000.1
Polymeric Insulated Cables — up to 1 kV

Primary standard for LV polymeric insulated and sheathed power cables for infrastructure distribution applications.

AS/NZS 5000.2
Aerial Bundled Cables — up to 1 kV

Aerial bundled cable standard for low voltage overhead distribution in infrastructure and public network applications.

AS/NZS 1429.1
HV XLPE Insulated Cables — above 1 kV

Governs polymeric insulated MV/HV power cables above 1 kV — applies to all MV infrastructure distribution cable up to 66 kV.

AS/NZS 3013
Electrical Installations — Classification of Fire & Mechanical Performance

Classification of fire and mechanical performance requirements for cables used in public infrastructure, specifying fire-resistant and fire retardant cable selection criteria.

AS/NZS 4507
Flame Propagation Characteristics — Electric Cables

Sets flame propagation performance requirements for electric cables used in infrastructure installations where fire spread must be controlled.

Project References

Specified in Major Infrastructure

EESA cables and enclosures have been specified and delivered across some of Australia's most significant infrastructure projects — airports, metro systems, tunnels, roads, and public buildings.

22
Projects Delivered
Airports · Metro · Roads · Tunnels
Project Types
AU · NZ
Regional Reach
Western Railways Darwin Airport Perth Freeway Expansion Sydney Road Infrastructure Canberra Metro Progress Rail WestConnex Sydney Metro Cross River Rail WA Road Infrastructure Robertson Barracks NT West Gate Tunnel Central Tunnelling M6 — NSW Western Sydney Airport Sydney Metro West Tunnel M12 — NSW Brisbane Move Western Harbour Tunnel Warringah Freeway Upgrade Tonkin Gap Alliance SSTOM

End-to-End Solutions

One Supplier. Complete Infrastructure Supply.

EESA supplies the complete cable and enclosure scope for infrastructure projects — from general purpose LV distribution through to fire rated HV systems — under one supply relationship with full compliance documentation.

01
Specify
Cable & Fire Rating Selection

Engineering support for cable selection — voltage ratings, fire performance classification, installation environment, and standards compliance for project specification packages.

02
Supply
Project-Scale Delivery

Full cable and enclosure scope supplied on schedule — LV to MV, general purpose to fire rated — across all project phases for major infrastructure programs.

03
Support
Compliance Documentation

Fire test reports, compliance certificates, technical datasheets, and installation guidance — ready for authority submissions and project handover documentation.

Infrastructure Project?

Your project. Our cable. One call.

Talk to EESA's team about power cables, fire-resistant cables, and fire rated enclosures for your infrastructure project — Australia, New Zealand, or the Pacific Islands.

Typically respond within one business day · Engineering team on call
EESA Typically replies in minutes
Hi there! 👋 Need a quote or product details? Share your info and our team will reply on WhatsApp shortly.